Taco 1611E3E1 1600 Series In-Line Centrifugal Pump 1/2HP 3PH
The USA-made in-line centrifugal Taco 1611E3E1 uses a 1/2 HP three-phase motor to safely pump 85 GPM through closed-loop heating or cooling networks.
- 85 GPM flow moves water fast
- 40 feet head overcomes piping friction
- 1.5 inch flange connects standard lines
- Sealed ball bearings cut maintenance downtime
- 175 psi casing takes heavy pressure
Description
Circulate industrial HVAC water with Taco 1611E3E1 1/2 HP three-phase in-line centrifugal pump for closed-loop heating and cooling. Its 208–230/460-volt motor runs at 1,725 RPM and delivers up to 85 GPM with 40 feet of head. The 1-1/2-inch two-bolt flange and 12-inch flange-to-flange length help contractors verify replacement fit. Confirm phase rotation, overload protection, piping alignment, and system curve before installation.
The close-coupled 1611E3E1 uses a cast-iron casing, one-piece cast-bronze impeller, alloy-steel shaft with cupro-nickel sleeve, and ceramic-face/EPT elastomer seal. Full-load current is listed as 2.0A or 1.0A, with 175 psi maximum pressure and a 40°F to 250°F fluid range. Sealed ball bearings require no routine lubrication, while external overload protection is required for the three-phase motor.
Key Features & Benefits
- 1/2 HP Three-Phase Motor: Fits industrial HVAC systems with verified 208–230/460-volt service.
- 85 GPM Maximum Flow: Provides a stated capacity reference for hydronic system selection.
- 40 Feet Maximum Head: Helps compare piping resistance and elevation requirements.
- 1-1/2-Inch Two-Bolt Flange: Supports replacement planning when the existing connection pattern matches.
- 1,725 RPM Operation: Gives technicians a defined motor-speed reference for equipment comparison.
- External Overload Required: Reminds installers to provide suitable motor protection.
- 12-Inch Flange-to-Flange Length: Helps confirm the available piping envelope.
- 48-Pound Dry Weight: Assists handling and pipe-support planning.
Why Choose Taco 1611E3E1 Three-Phase
This Taco 1600 Series pump provides published hydraulic, electrical, temperature, pressure, and dimensional data for closed-loop HVAC replacement work. Its 1/2 HP configuration suits systems needing more capacity than a smaller 1/3 HP circulator.
- Build: Cast iron, cast bronze, alloy steel, cupro-nickel, and ceramic/EPT components define the assembly.
- Value: Published operating data can reduce selection errors before a scheduled shutdown.
- Audience: Fits HVAC contractors, boiler technicians, facility engineers, and industrial maintenance teams.
Applications & Use Cases
Use this pump in industrial closed-loop heating and cooling systems within the listed 85 GPM and 40-foot limits. Check the 1-1/2-inch flange, 12-inch flange-to-flange length, pipe supports, valve clearance, motor access, and external overload arrangement. Keep fluid conditions between 40°F and 250°F and pressure below 175 psi.
Warranty & Support
- Warranty Terms: Warranty duration, coverage, exclusions, and registration requirements require confirmation from the authorized seller.
- Service Requirements: Confirm whether authorized service is required for warranty claims.
- Model Verification: Match Taco 1611E3E1, 1/2 HP, three-phase, and SKU 1611E3E1-1/2-3 to the order.
Verify voltage and phase rotation, align the flange, purge air, inspect strainers, and check for leaks during commissioning. Compare the running point with the actual pump curve before startup. Purchase the Taco 1611E3E1 three-phase in-line centrifugal pump at Mulmotor.com for genuine equipment, applicable warranty coverage, and pump support.
Taco 1611E3E1 1/2HP 3PH Pump Specs
| Technical Parameter | Official Specification |
|---|---|
| Brand & Series | Taco Comfort Solutions - 1600 Series |
| Model Number/SKU | 1611E3E1 (Cast Iron) |
| Country of Origin | USA |
| Pump Type | In-Line Centrifugal Pump |
| Horsepower (HP) | 1/2 HP |
| Voltage (V) & Phase (PH) | 208-230V/460V / 3 PH / 60Hz |
| Amperage (FLA) | 2.0A / 1.0A (Typical) |
| Motor RPM | 1725 RPM |
| Motor Type | NEMA 56 Frame / ODP High Efficiency |
| Connection Type | 2-Bolt Flange |
| Connection Size (Inches) | 1-1/2" (Standard) |
| Body Material (Casing) | Cast Iron (ASTM A48 Class 30) |
| Impeller Material | One-Piece Cast Bronze |
| Shaft Material | Alloy Steel w/ Cupro-Nickel Sleeve |
| Mechanical Seal Type | Ceramic Face / EPT Elastomer |
| Max Flow Rate (GPM) | 85 GPM |
| Max Head (Feet) | 40 Feet |
| Max Operating Pressure (PSI) | 175 PSI |
| Max Fluid Temperature (°F/°C) | 250°F (121°C) |
| Min Fluid Temperature (°F/°C) | 40°F (4°C) |
| Drive Type | Close-Coupled |
| Bearing Type | Maintenance-Free Sealed Ball Bearings |
| Flange-to-Flange Length | 12 Inches |
| Shut-off Head | 42 Feet |
| Thermal Protection | External Overload Required |
| Service Factor | 1.15 |
| Dry Weight (lbs/kg) | 48 lbs (21.8 kg) |
| Application Suitability | Industrial Closed-Loop Heating/Cooling |
| Compliance | UL Listed / CSA Approved |
| SEO Usage Profile | Industrial HVAC / 3-Phase Power Facilities |